MT95K2
This product is discontinued. Information is for reference purposes.
Click here for current products.
Software Release Notes
| Version 15.7/25.7 |
|
Date: 11/2/00 |
New Features:
• Time marker settings based on TMP2 board are now saved with the mode file.
Corrections: None.
Notes: None.
|
| Version 15.6/25.6 |
|
Date: None |
New Features: None.
Corrections: None.
Notes:
• Not officially released.
|
| Version 15.5/25.5 |
|
Date: 12/14/99 |
New Features: None.
Corrections:
• Improved the hard drive status for SCP1 data capture.
Notes: None.
|
| Version 15.4/25.4 |
|
Date: 04/12/99 |
New Features: None.
Corrections:
• Enhanced autorange.
• Event-based grids disabled when no TMP2 is present.
Notes:
• SCP1B firmware V 1.8 improves SCSI data capture lockup when aborting.
|
| Version 15.3/25.3 |
|
Date: 9/25/98 |
New Features:
• Removes the test for GPIB functionality on boot up.
Corrections: None.
Notes:
• Because the GPIB chip has been discontinued, new K2 recorders won't have the GPIB chip installed unless specifically requested.
|
| Version 15.2/25.2 |
|
Date: 9/21/98 |
New Features:
• Enhances Quick Range to improve the ability to calibrate to non-zero values.
Corrections:
• DOS file date created when saving files to the floppy disk for years set to 2000 or higher.
Notes: None.
|
| Version 15.1/25.1 |
|
Date: 6/16/98 |
New Features:
• Provides additional derived timing markers for the TMP2.
Corrections: None.
Notes:
• Requires TMP2 firmware v1.2.
|
| Version 15.0/25.0 |
|
Date: 4/29/98 |
New Features:
• For the TMP2, adds the ability to control four event markers which can toggle at different time rates.
Corrections: None.
Notes:
• Requires EPROM changes to both printhead control boards as well as TMP2 firmware v1.1
|
| Version 14.9/24.9 |
|
Date: 3/17/98 |
New Features:
• Adds Quick Range feature, which allows a user to calibrate the amplifiers to an external source.
Corrections: None.
Notes:
• Version 14.8 never officially released due to a bug problem with Standard Recorder mode.
|
| Version 14.7/24.7 |
|
Date: 5/29/97 |
New Features: None.
Corrections:
• Modified the on-demand buffer printing.
Notes: None.
|
| Version 14.6/24.6 |
|
Date: 4/17/97 |
New Features: None.
Corrections:
• Enhances host lock-out during data archive.
Notes: None.
|
| Version 14.5/24.5 |
|
Date: 1/31/97 |
New Features:
• Adds motor speed calibration compensation, allows user to adjust speed +/- 2%.
Corrections: None.
Notes: None.
|
| Version 14.4/24.4 |
|
Date: 12/31/96 |
New Features:
• Adds alarm color for VOP-3, waveform will change color based on user-defined limits.
Corrections:
• Modifies data capture for captures with roll over from one month to another.
Notes: None.
|
| Version 14.3/24.3 |
|
Date: 10/16/96 |
New Features: None.
Corrections:
• Modified on-demand buffer action.
• Improved IRIG time decoding.
Notes: None.
|
| Version 14.2/24.2 |
|
Date: 9/6/96 |
New Features:
• Adds support for new revision DWP2 board with synchronous recording.
• Auto ID now prints immediately when starting a capture playback.
• Adds new DWP2 host commands.
Corrections:
• Modifies mode upload via RS232.
• Improves DWP2 communication.
Notes: None.
|
| Version 14.1/24.1 |
|
Date: 1/3/96 |
New Features:
• Adds support for SCP1 sample rates of 1,2 and 5 Hz.
• Adds utility to calculate absolute playback time in terms of date and time.
• Display labels can now be displayed during data capture.
• Adds LOAD/LOAD+RUN choice when loading a mode from disk.
• Adds clock trigger source.
Corrections: None.
Notes:
• SCP1 firmware upgrade required for this version of K2 system software.
• Version 14.0 was not released.
|
| Version 13.9/23.9 |
|
Date:10/23/95 |
New Features:
• Adds data capture time stamp to record select menu in data playback mode.
• Adds a COPY command to the zero/gain menus.
Corrections:
• Improves the ARCW host command for data captures larger than 512K.
Notes: None.
|
| Version 13.8/23.8 |
|
Date: 8/30/95 |
New Features: None.
Corrections:
• Improves the bridge type selection for the AWP4.
Notes: None.
|
| Version 13.7/23.7 |
|
Date: 6/15/95 |
New Features: None.
Corrections:
• Improves signal conditioner reporting for AWP2 and AWP2-40 after auto-calibration.
Notes: None.
|
| Version 13.6/23.6 |
|
Date: 5/25/95 |
New Features: None.
Corrections:
• Improves the CLHS host command.
Notes:
• Version 13.5 was not released.
|
| Version 13.4/23.4 |
|
Date: 2/14/95 |
New Features: None.
Corrections:
• Enhances range settings for modes downloaded via host control.
Notes: None.
|
| Version 13.3/23.3 |
|
Date: 1/9/95 |
New Features:
• Added new CLHS command, allowing the host to clear the halted flag generated by the CHRT 0 command.
Corrections: None.
Notes: None.
|
| Version 13.2/23.2 |
|
Date: 10/8/94 |
New Features:
• Adds user scaling to the zero/gain menus.
• Enhances the operation of the external keyboard input from the VOP1 board.
• Adds support for the new AWP1 board (optical isolation).
Corrections:
• Coordinates the playback window command for both SCP1 and DCP1 boards.
Notes: None.
|
| Version 13.1/23.1 |
|
Date: 7/1/94 |
New Features:
• Adds mode upload/download feature via host control.
Corrections: None.
Notes: None.
|
| Version 13.0/23.0 |
|
Date: 5/12/94 |
New Features:
• Adds scaling feature for DWP1 via front panel and host control.
Corrections: None.
Notes: None.
|
| Version 12.9/22.9 |
|
Date: 3/17/94 |
New Features:
• Adds support for DSP2 digital signal processing module
Corrections: None.
Notes:
• Necessary upgrade for DSP2 board.
|
| Version 12.8/22.8 |
|
Date: 3/17/94 |
New Features:
• Adds auto-archive capability, data stored on a DCP1 can be archived to an SCP1.
• Adds two mean filters for the AWP4.
Corrections:
• Enhances signal conditioner reporting when using zero suppression with an AWP1.
• Increases the reliability of RS232 interface.
• Enhances the system event marker archive and upload.
Notes:
• Requires new AWP4 firmware for mean filtering.
|
| Version 12.7/22.7 |
|
Date: 12/20/93 |
New Features:
• Adds AUTORANGE ALL feature.
• Adds FFT ZOOM feature.
• Adds numeric playback as a choice for playback settings.
• Adds auto-stacked parallel capture (data can now be stored on the DCP1 and SCP1 simultaneously).
• Adds signal conditioner reporting for AWP4.
• Adds the ability to arm a capture via the utility port.
• Adds support for new motor power tables.
Corrections:
• Improves XON/XOFF handshaking.
Notes:
• Requires EPROM update for SSB board, as well as new motor wiring harness (IMPORTANT).
|
| Version 12.6/22.6 |
|
Date: 8/20/93 |
New Features:
• Adds support for the AWP4 dc-bridge module.
• Adds the analog settings to data captured on DCP1 and SCP1 boards.
• Adds a "stuck-key" check on power-on.
• Dashes are now displayed for time on playbacks with external sample rate.
Corrections:
• Improves data playback time code (IRIG) resolution.
• Enhances event marker enable via host control.
Notes:
• VOP1 and TMP1 firmware upgrades released.
• Version 12.5 was not released.
|
| Version 12.4/22.4 |
|
Date: 4/15/93 |
New Features:
• Adds support for two TGP1 boards, a total of 16 channels of triggering.
• Adds VOP1 screen dump feature.
• Adds support for playback sample numbers for VOP1.
• Adds GROUND ALL/UNGROUND ALL feature under the zero/gain menu.
• Adds enhanced signal conditioner reporting - left and right grid values.
• Adds support for zero position accuracy to 1/10th of 1 percent.
• Adds support for enable/disable DWP1 system event driver.
Corrections:
• Improved data playback from SCP1 to VOP1.
• Enhances host control commands such as TSRC, CHAN?, GRSY, and GRMN.
Notes:
• VOP1 requires v1.3 firmware upgrade.
|
| Version 12.3/22.3 |
|
Date: 3/25/93 |
New Features:
• Adds trigger setting to general help sheet.
• The VOP1 can now be set to a different chart than the paper output.
• Adds two new time mark selections - 3.6 and 6 seconds.
• Adds new host control commands for VOP1 support.
• Soft key #10 now operates as a LOCAL key when display labels are on.
Corrections:
• Slew rate triggering is allowed when window triggering is disabled on power-up.
• The VOP1 now operates correctly when installed in slot 9 with no other peripherals enabled.
• An asterisk (*) is not allowed in the file names on the floppy drive.
Notes:
• VOP1 requires v1.2 firmware upgrades released..
|
| Version 12.2/22.2 |
|
Date: 2/10/93 |
New Features:
• Support for new SCP1A board, with DAT backup feature.
• Adds time and date to the calibration report.
• The TMP1 has been enhanced with more accurate end-of-capture time stamp.
Corrections:
• Improved host download after power-up.
• Zero position on the channel status report prints correctly.
• Improved the ARMC? host control command.
Notes:
• SYSCON, SCP1 and VOP1 firmware upgrades released.
|
| Version 12.1/22.1 |
|
Date: 05/20/08 |
New Features:
• Adds password security feature.
• Adds support for SCP1 external sample rate.
Corrections:
•Event marker positions can now be set from host control.
• Slot enabling for DI488 and AWP1 boards.
Notes:
• SYSCON and SCP1 firmware upgrades released.
|
| Version 12.0/22.0 |
|
Date: 2/31/92 |
New Features:
• Adds darker printing for text and timing marks at various speeds.
• Adds FFT analysis feature.
• Adds full page mark for system event. Adds trace thickness control.
• Adds slot enable/disable feature.
• Adds plotter mode for host control, can also work with files from floppy disk (using K2 specific format).
Corrections: None
Notes:
• SCP1 and VOP1 firmware upgrades released.
|
| Version 11.9/21.9 |
|
Date: 11/25/92 |
New Features:
• Adds support for SCP1 board.
Corrections:
• Improves speed change sequences.
• The data analysis menu now indicates when no data capture board is installed.
• Enhnaces event marker captures immediately after power-up.
• Augments data capture from DCP2.
• Improves data upload via host control.
Notes:
• Master TPH, SCP1, and VOP1 firmware upgrades released.
|
| Version 11.8/21.8 |
|
Date: 11/10/92 |
New Features:
• Adds the Data Analysis (Record Report) feature.
• Adds support for data capture record upload to host.
• Adds Capture Duration calculator feature.
Corrections:
•Improves abort key function during Auto Range.
• Enhances host control with AWP3.
Notes:
• Master TPH and VOP1, and DCP2 firmware upgrades released.
• Version 11.7 not released.
|
| Version 11.6/21.6 |
|
Date: 9/30/92 |
New Features:
• Adds support for DI488 peripheral.
• Adds support for AWP2-40 analog input board.
• Adds VGA support for VOP1 board.
• Support for IDP1 peripheral (specific Boeing application).
• Adds calibration report.
• Adds Auto Range feature.
• Various host control enhancements.
Corrections: None
Notes:
• Master TPH and VOP1 firmware upgrades released.
|
| Versions 11.0 through 11.5 |
|
Date: N/A |