Investor | Technical Support | Contact Us | 877-867-9783
600 East Greenwich Ave. West Warwick, RI 02893
600 East Greenwich Ave. West Warwick, RI 02893
The ADP-4810 Active Differential Probe provides for one-channel of high voltage measurements. Attenuation is 20:1 or 200:1. The probe can withstand up to 1000 Vrms.
Input Voltage (max. differential):
+/- 140 VDC at 20:1 attenuation
+/- 1400 VDC at 200:1 attenuation
Common Mode Maximum: +/- 1400 VDC or 1000 Vrms
CMRR (Typical): -60 dB at 20 kHz
Bandwidth: DC to 25 MHz (-3dB)
Accuracy: +/- 2%
Risetime: 14 nsec
Input Impedence:
4 Mohm/10 pF, each side to GND
8 Mohm/5pF between inputs
Power Requirements: 4 xAA cells
Weight (less batteries): 0.62 lbs (285 gm)
Dimensions: 6.6" x 2.4" x 0.8" (168 x 62 x 20 mm)
Part Number: 25765000